■ Features
Protects telephone line equipment (telephone, modem, facsimile etc.)
against surge
and over voltage
(UL1459, CSA-22.2 No. 225-M90).
|
■ Part number system
DSSV |
|
301 |
L |
|
YD |
|
|
|
|
|
|
Series |
|
DC
Spark-over
voltage(Vs) |
DC
Spark-over
voltage tolerance |
|
Shape |
| |
|
|
|
|
|
|
|
The
first two digits are significant,
and the third is number of zeros. |
|
|
|
|
|

|
■ Dimensions

|
■ Characteristics
|
Series |
Part Number |
DC spark-over
voltage Vs |
Insulation resistance
IR |
Electrostatic
capacitance
1kHz-6V max. |
Surge current
capacity 8/20μsec. |
Surge life
test |
UL recognized |
UL 497A 3) |
DSSV |
DSSV-201M-YD |
200V (160~240) |
100MΩmin. |
DC
100V |
2pF
max |
400A |
FCC 1cycle 1) |
O |
DSSV-301L-YD |
300V (255~345) |
DOC 1cycle 2) |
DSSV-401M-YD |
400V (320~480) |
DC
250V |
O |
|
| 1): |
FCC10/560μsec. 100A ±3times, 10/160μsec.
200A ±3times
|
| 2): |
DOC 1cycle 10/1000μsec. 1KV-12times, 100/1000μsec.
1KV-12times respectively. |
| 3): |
UL Standard UL 497A File No. E131010(N) |
|
■ Surge Response characteristics (Reference)



|
■ Overvoltage cut off properties of DSSV type
Part number |
DSSV-301L-YD, DSSV-401M-YD
|
Applied conditions |
AC 600V-40A-1.50sec. |
AC 600V-7A-5sec. |
AC 600V-2.2A-30min.
|
Rate of ignition n=100 |
0 |
0 |
0 |
Overvoltage testing is
required in both UL60950
and CSAC22.2 No.225M90.
The DSSV
is effective in protecting
against these overvoltage
conditions by opening
the circuit. |
| |